Curing and guide for vulcanizing machine
Release Time: 2024-09-29 15:15

1, check the amount of hydraulic oil before use, the height of hydraulic oil is 2/3 of the height of the lower frame, the amount of oil should be added in time when the amount is insufficient, and the oil needs to be fine filtered before injection. Add pure 20 # hydraulic oil into the oil injection hole of the lower frame, and the oil level height is seen by the oil marker, which is generally added to the 2/3 height of the lower frame.


2. Check the lubrication between the column shaft and the guide frame and refuel in time to maintain good lubrication.


3, turn on the power, move the operation handle to the vertical position, so that the oil return port is closed, press the motor start button, the oil from the oil pump enters the cylinder, driving the plunger up, when the hot plate is closed, the oil pump continues to supply oil, so that the oil pressure rises to the rated value, press the registration stop button, so that the machine is in the shutdown pressure protection (i.e., timing vulcanization) state, when the vulcanization time is reached, Move the handle to lower the plunger and open the mold.


4, the temperature control of the hot plate: close the rotation button, the plate begins to heat, when the temperature of the plate reaches the pre-set value, the heating will automatically stop. When the temperature is below the set value, the plate automatically heats to maintain the temperature at the set value.


5, tire vulcanization motor control: press the motor start button, AC contactor power, oil pump work, when the liquid pressure reaches the setting value is the AC contactor disconnected, began to automatically record the vulcanization time, when the pressure drops oil pump motor start automatic pressure, reach the set vulcanization time, whistle, tell the vulcanization time has arrived, you can open the mold, press the ring stop button, Move the manually operated valve to lower the plate and proceed to the next cycle.